CeraPower 2.0 is used to cure HyCeram colors under pressure at 120°C (approx.248°F) under 4 bar pressure within 60 minutes. Attach your air compressor (not included) to the unit and fill the curing chamber with Thermo Liquid solution (8213935). When loading your workpieces, avoid introducing air bubbles. Can arrange workpieces on a holding accessory but still need to slowly introduce the holder into the liquid. After curing, thoroughly rinse and dry your pieces.
Technical Data:
HxWxD: 230x290x330mm (approx. 9"x11-1/2"x13")
Empty weight: 10 kg (22 lbs.)
Power consumption: 450W
Min. Operating pressure: 3 bar
Max. Operating pressure: 4.2 bar
Max. Operating temperature: 120°C (approx. 248°F)
Volume: 2 Liter (approx. 1/2 gallon)
Electrical: 115V, 60 Hz
Min. compressor pressure: 4 bar
Max. compressor pressure: 10 bar
Basic instructions:
Connect the CeraPower 2.0 device to a compressed air source.
Use the adjustable screw to adjust the standard working pressure to 4 bar.
Fill the pressure chamber to the marked line with Thermo Liquid (8213935)
Set the timer to 60 minutes and press start.Thermo Liquid can be reused approximately 20 times - replace when liquid turns a slight yellow color or appears cloudy